Shockwave electromagnetic shock wave machine,Lipolaser fat removal, CET AND RET 448K monopolar rf
Shockwave 448K and Lipolaser Body Care System
Theory
(1) Shockwave
A shockwave is defined as a wave with a rapid increase of pressure within a very short time and then having a gradual decrease of pressure with a small negative pressure phase. Shockwave is aimed at the affected areas that are the source of chronic pain. The influence of the shockwaves causes to the dissolution of calcium deposits and leads to better vascularization. The after-effect is relief from the pain.
(2) 448K
① CET Theory
The cap is a core technology of constant room temperature of the epidermis and deep heating of the radio frequency, which ensures that the skin is comfortable and undamaged, and then uses the cap to generate heat conduction to precisely reach the deeper layers of the skin, stimulating the ions and charged colloidal particles in the organism to produce rapid movement or vibration and heat from sassafras, while heating the collagen tissue in the dermis under the effect of polarized molecular resonance technology. When the heat energy of the collagen tissue in the deeper layer of the skin reaches 45℃-60℃, it naturally produces immediate contraction and stimulates the secretion of more new collagen to fill the gaps of the atrophied and lost collagen, and rearrange it to rebuild the soft scaffolding of the skin, ultimately achieving the effect of skin tightening, filling in wrinkles and restoring skin elasticity and lustre.
② RET Theory
The projection of high frequency energy into the body produces deep heat from the dermis of the skin and decomposes body fat for the purpose of weight loss. When high-frequency current is applied to the body tissues, there is little ionic movement due to its very low vibration amplitude, and no electrochemical reaction or electrical decomposition is produced. If high frequencies are conducted to the body, the body tissues will heat up. This is because when a high frequency current is applied to the body, the molecules that make up the tissues vibrate every time the current changes direction, creating rotational, twisting and conflicting motions by friction with each other.
(3) Lipolaser
The main role of the low-energy laser bio-stimulation (Bio stimulation), that is, through the give appropriate energy to stimulate the biological cells and induce or strengthen a number of physiological responses, including to promote local blood circulation, regulate cell function, enhance immune function, promote cell metabolism and proliferation.
Wavelength of 650nm red laser just in human eye color of the visible spectrum, so we can see the red light 650nm can penetrate the organization up to 8-10mm, the effective activation and repair cells, stimulate the synthesis of cell metabolism, for the superficial cells biochemical stimulation and hyperemia. Irradiation meridian points to stimulate the meridian points related organizations, the skin tissue will not cause harm to exempt patients fear of needles, and also have the function to stimulate the meridians in a healthy way.
(4) EMS
Electrical Muscle Stimulation(EMS), also known as neuromuscular electrical stimulation(NMES) or electromyostimulation, is a protocal that elicits a muscle contraction using electrical impulses that directly stimulate your motor neurons. The stimulation creates muscle contractions that can be quick and frequent, fat with long pauses, or contractions that are held for several seconds or minutes at a time.
According to human neurology, 600 times electronic pulse currents per minute directly act on muscle nerve, can deeply reach the fat body, stimulate the most intensive neuro to induce muscle to generate shrinkage exercise. In the rapid active state of fat cells, the local fat layer is sufficient exercise, the body's basal metabolism is improved, and the effect is still continued within 24 hours after use. The kinetic energy is transformed into slimming energy, quickly eliminates human fat, and achieves more slimming effect than traditional methods, and tightens the curve of the whole body.
Application
(1) Shockwave
Cellular: Increase in cell membrane transmittance by improving ionic channels activity, stimulation of cell division, stimulation of cellular cytokines production.
Reproduction of vessels in the area of tendons and muscles: Improvement of blood circulation,
increase in concentration of growth factor beta 1, chemotactic and mitogenic effect on osteoblasts.
Effect on nitrogen oxide system: Bone healing and remodeling.
Improvement of macro-circulation and metabolism.
Dissolution of calcified fibroblasts.
Supports the production of collagen.
Reduction in tissue tension.
Analgesic effect.
(2) 448K
① CET Mode
Lifting and tightening, whitening and rejuvenating skin.
Control acne and improve wrinkles.
Burning fat and reducing pain.
Improve constipation and increase elasticity.
Tighten postpartum sagging and soothe sore muscles.
Relax stiff joints.
Assist in the introduction of serum.
② RET Mode
Lymphatic drainage.
Increased blood circulation.
Repair of cells, nerves, bones, muscles and ligaments.
Regulation of endocrine secretion.
Improves sleep.
Brightens skin tone.
Improves breast sagging and enlargement problems.
Body shape and cellulite problems on the legs.
Weight loss.
Burning visceral fat.
(3) Lipolaser
Fast fat reduce, weight loss.
Stimulate lymph drainage.
Therapy for all bone illnesses.
Increase cell energy, improve the metabolism.
Parts Introduction
Parameters
Shockwave | Power | ≤240W |
Frequency | 1Hz-16Hz | |
CET | Power | ≤100W |
Frequency | 448K | |
RET | Power | ≤180W |
Frequency | 448K | |
Lipolaser | Wavelength | 650nm and 980nm |
Laser Source | Mitsubishi diode laser ML101J27 | |
Laser Type | Low intensity diode laser | |
Quantities of Lamps | 64pcs | |
Each Lamp Energy | 100mW – 350mW (pulse) | |
Laser Working Mode | Continuous and Pulse | |
Laser Pads | 4pcs | |
EMS | Frequency | 500Hz |
Plate Size | 26mm*14mm | |
Number of plates | 16pcs | |
Power | ≤600W | |
Touch Screen | 12inch Touch Screen | |
Cooling System | Air Cooled | |
Voltage | AC 110V/220V; 50Hz-60Hz | |
Environmental requirement | 10。C to 40。C. Non-condensing humidities below 75% RH | |
Packing Size | 92cm*46cm*55cm | |
N. W./G. W. | 20kg/35kg |
Operation